The recycle step's checks spoke of "the realtime recycle" even when
run with a watch shorter than the five-minute connection age, as module
CI does. They now say what they check: live for the whole watch (plus
"across a realtime recycle" when the watch is long enough), and never
remounted.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
Reproduction harness for what the first production Signage deployment
found. With EKKLESIA_SMOKE_DISPLAY_DEVICE=1, the split smoke starts a
second headless Chromium (the "kiosk") whose profile directory is a
Docker volume. It pairs that kiosk through the real flow, closes it
cleanly, restarts it on the same profile, and then runs injected-failure
scenarios: two pages on one credential, a connectivity blip, one refused
viewer-session request, one refused realtime connection, a cross-origin
image-caching probe, a full realtime recycle, and revocation.
Every DevTools command and page-side request has its own deadline, and
each step has a budget. A step that overruns prints the exact call it
was waiting for. The proxy's "aborting with incomplete response" lines
are listed afterwards by UTC time and path only.
Off by default: several scenarios expect Signage and fail on today's
v0.1.1, by design.
Co-Authored-By: Claude Opus 5.5 <[email protected]>